Rack and stack is the physical part of installing IT equipment: unpacking servers, storage and network devices, fitting them into racks, connecting power and cables, and labelling everything so it can be found later. It sounds simple, but a rushed job causes problems that only show up months afterwards, such as unlabelled cables, blocked airflow or overloaded power circuits.

What the work usually includes

  • Checking delivered equipment against the order and recording serial numbers
  • Fitting rails and mounting equipment at the agreed rack positions
  • Connecting power and network cables and dressing them neatly
  • Labelling devices, cables and ports to the agreed scheme
  • Powering on and confirming that each device starts and shows the expected status
  • Photographing the finished racks and reporting what was done

Prepare the site before the engineer arrives

  • Confirm the rack space is free and has the height, in rack units, that the equipment needs.
  • Check power: the number and type of sockets, and that the circuits can carry the extra load.
  • Check cooling and airflow, and which way the equipment should face.
  • Agree the cable routes, the lengths needed and the labelling scheme.
  • Arrange access: who needs permits, escorts or inductions, and the visiting hours.
  • Book the delivery, name a person to receive the equipment and set aside a place to unpack it.

Write the plan down

A rack plan is a simple diagram or table that shows what goes where: the device, the rack, the position, the power feed and the network port at each end. With a plan, the engineer can work through it step by step and you can check the result against it afterwards. Without one, small guesses add up.

Common mistakes

  • Ordering rails or cables that do not match the equipment
  • Mixing up the front and back of the rack, so airflow works against the equipment
  • Putting heavy equipment high in the rack instead of low down
  • Skipping labels to save time
  • Forgetting small parts such as screws, cable ties and power leads

After the job

Ask for a short report with photos of each rack, the serial numbers and any problems found. Keep it with the rack plan so the next person starts from an accurate record.